GF Signet 3-2777-1 DryLoc ORP Electrode 3-2777-1
Signet 3-277X-X Threaded DryLoc pH/ORP Electrodes.MOUNTING: In-Line / Vertical / Submersible, MAX PRESSURE: 100 psi (6.9 bar), COMPATIBILITY: Signet Models 2750 and 2760.
GF Signet 3-2777-1 Threaded DryLoc pH-ORP Electrodes. Wetted Materials: Ryton, PTFE, FKM, glass, Connection: Durable DryLoc® with gold plated connections, Compatible Preamp/Sensor Electronics: 2750 and 2760.
The Signet 2774-2777 pH and ORP Electrodes feature a unique foulproof DryLoc® connector with gold-plated contacts designed specifically for use with the Signet 2750 and 2760 preamplifiers and sensor electronics. These dependable and highly responsive electrodes feature a PTFE double reference junction with KNO3 in the front chamber to block various poisoning ions. Embedded positioning of the temperature element in the pH sensing tip allows the temperature response to be quick and accurate. The electrodes are offered with either flat or bulb style sensing elements. The flat versions allow sediment and particles to sweep past the measurement surface, minimizing risks of abrasion, breakage and coating. The bulb versions can be used for general purpose applications. Due to the specially designed chambers which keep electrolyte in place, all versions can be mounted at any angle, even inverted.
- Wetted Materials: Ryton, PTFE, FKM, glass
- Connection: Durable DryLoc® with gold plated connections
- Compatible Preamp/Sensor Electronics: 2750 and 2760
- Compatible Instruments: Use the 2760 preamplifier with the Signet 8750; Use the 2750 sensor electronics with the Signet 8900, 9900 or 9950 instruments
- Additional Features: Quick temperature response and can be mounted upside-down
- In-line Mounting styles: Use the sensors 3/4 inch thread to mount to any in-line tee
- Submersible mounting: Available using the back of the preamplifier or sensor electronics
- Applications: Water treatment, water quality monitoring, some harsh chemicals
- Water Treatment and Water Quality Monitoring
- Cooling Tower and Boiler Protection
- Aquatic Animal Life Support Systems
- Pool and Spa Control
- Neutralization Systems
- Patented DryLoc connector with gold-plated contacts
- Special design allows mounting at any angle
- Quick temperature response
- High temperature versions available
- Easy sensor replacement using DryLoc electrode connector
- Mounts into standard ¾ inch threads
- Compatible with all pH/ORP and other suppliers instruments
| Compatibility | Signet Models 2750 and 2760 |
|---|---|
| Operating Range 2774/2776 | 0 to 14 pH |
| Operating Range 2775/2777 | ±2000 mV (ORP) |
| Process Connection | ¾ in., for use in reducing tees up to 4 in. |
| Reference Electrolyte | KNO3/KCl polyacrylamide gel |
| Reference Element | Ag/AgCl |
| Wetted Materials Body | Ryton® |
| Wetted Materials Reference junctions | PTFE |
| Wetted Materials Sensing surface | pH, Glass membrane, ORP, Platinum |
| Wetted Materials O-rings | FPM |
| Operating Temperature | 0 °C to 85 °C / 32 °F to 185 °F |
| Max. Operating Pressure | 6.9 bar / 100 psi |
| The best storage temperature for the 277x pH and ORP is | 0 °C to 50 °C / 32 °F to 122 °F |
| The electrode glass will shatter if shipped or stored at temperature | below 0 °C (32 °F) |
| The performance life of the electrode will shorten if stored at temperatures | above 50 °C (122 °F) |
| In-line/Vertical Mounting | Use the electrodes ¾ inch threads to install into pipe fitting. Electrode can be mounted at any angle. |
| Submersible Mounting | Use threads on Model 2750 or 2760; requires ¾ inch NPT or ISO 7/1-R 3/4 male threaded extension. |
| Temperature Sensor pH | 3 KΩ or PT1000 RTD |
| Temperature Sensor ORP | none |