2760 DryLoc pH/ORP Preamplifier and Connectors

The Signet 2760 pH/ORP Preamplifiers features the DryLoc® connector, providing a robust connection to Signet DryLoc® electrodes. The 2760 preamplifier allows any DryLoc® pH/ORP electrode to work with Signet ProcessPro® and ProPoint™ pH/ORP instruments. It is also sold as a simple connector for use with other manufacturers' instruments that do not require a preamplified signal. The DryLoc® electrode connector system quickly forms a robust assembly for submersible and in-line installations. NEMA 4X junction enclosures extend the preamplifier cable to long distances. The 2760 Submersible Preamplifier can also be used as an In-line Preamplifier when used with the ¾ in. or 1 in. threaded sensors including the 2724, 2774 and 2764 series electrodes. The 2760 In-line Preamplifier can be used with Signet fittings up to DN100 (4 in.) and wet-tap assemblies.

pH/ORP:
  • Compatible Instruments: Signet 8750
  • Connection: Durable DryLoc® with gold plated connections
  • Mounting styles: In-line integral mount and submersion
  • Compatible sensors: 2724 - 2726, 2735, 2756 - 2757 Wet-Tap, 2764 -2767, 2774 - 2777
Fields of Application:
  • Water and Wastewater Treatment
  • Neutralization Systems
  • Scrubber Control
  • Effluent Monitoring
  • Surface Finishing
  • Flocculent Coagulation
  • Heavy Metal Removal and Recovery
  • Toxics Destruction
  • Sanitization Systems
  • Aquatic Animal Life Support Systems
  • Pool and Spa Control
Advantages:
  • In-line integral mount and submersible installation versions
  • Compatible with pH or ORP sensors
  • Patented DryLoc® connector provides a quick and secure connection to the sensor
Standards:
  • CE
  • FCC
  • RoHS compliant
  • China RoHS
Specification
Compatible ElectrodesSignet DryLoc&reg; pH and ORP Electrodes Models 2724-2726, 2756-2757 Wet-Tap 2764-2767, 2774-2777, All pH sensors used with the 2760 must have a 3K Temperature sensor
Operating Range pH0 to 14 pH
Operating Range ORP&plusmn;2,000 mV
Response Time* pH< 6 sec. for 95% of change
Response Time* ORPapplication dependent
Materials In-lineValox® (PBT)
Materials SubmersibleCPVC
Electrical Cable4.6 m (15 ft) supplied, 120 m (400 ft) max, 6 cond., foil shield with drain wire, 24 AWG
Operating Temperature Submersible0 &deg;C to 85 &deg;C /32 &deg;F to 185 &deg;F
Operating Temperature In-line0 &deg;C to 110 &deg;C / 32 &deg;F to 230 &deg;F
Storage Temperature-20 &deg;C to 85 &deg;C / -4 &deg;F to 185 &deg;F
Relative Humidity0 to 95%, non-condensing (without electrode connected)
Enclosure SubmersibleNEMA 6P/IP68 with electrode and watertight conduit and/or extension pipe connected
Enclosure In-lineNEMA 4 with electrode and watertight conduit and/or extension pipe connected
Accessories
GF Signet 3822-7115 pH/ORP Buff er Solutions 3822-7115
GF Signet 3-2759 pH/ORP System Tester 3-2759
GF Signet 3822-7004 pH/ORP Buff er Solutions 3822-7004
GF Signet 3822-7007 pH/ORP Buff er Solutions 3822-7007
GF Signet 3822-7010 pH/ORP Buff er Solutions 3822-7010
GF Signet 5523-0624 Cable, 24 AWG, 6 cond./per foot 5523-0624