GF Signet 3-2750-7 DryLoc pH/ORP Sensor Electronics
DryLoc pH/ORP Sensor Electronics for process monitoring and control
GF Signet 3-2750-7 is the DryLoc pH/ORP Sensor Electronics for process monitoring and control.
GF Signet 3-2750-7 DryLoc pH/ORP Sensor Electronics
GF Signet 3-2750-7 is the DryLoc pH/ORP Sensor Electronics for process monitoring and control.
Specifications and Features
2750 DryLoc pH/ORP Sensor Electronics
The Signet 2750 pH/ORP Sensor Electronics featuring the DryLoc® connector, provides a variety of functions to suit various requirements.
The Signet 2750 pH/ORP Sensor Electronics has a preamplified signal and features two different outputs: a two-wire 4 to 20 mA loop output with EasyCal function or a digital (S3L) output which allows for longer cable lengths and is compatible with the Signet 8900 or 9900 instruments.
The 2750 self-configures for pH or ORP operation via automatic recognition of the electrode type. The optional EasyCal feature allows simple push-button calibration and includes an LED indicator for visual feedback.
The DryLoc® electrode connector quickly forms a robust assembly for submersible and in-line installations. NEMA 4X junction enclosures are integral parts of the 2750 in-line version and are also available as accessories for the submersible 2750.
The 2750 Submersible Preamplifier can also be used as an In-line amplifier when used with the ¾" or 1" threaded sensors including the 2724, 2774 and 2764 series electrodes. The 2750 in-line Preamplifier can be used with Signet fittings up to DN100 (4 in.) and wet-tap assemblies.
Fields of Application:
- Water and Wastewater Treatment
- Neutralization Systems
- Scrubber Control
- Effluent Monitoring
- Surface Finishing
- Flocculent Coagulation
- Heavy Metal Removal and Recovery
- Toxics Destruction
- Sanitization Systems
- Aquatic Animal Life Support Systems
- Pool and Spa Control
Advantages:
- In-line integral mount and submersible installation versions
- Automatic temperature compensation
- Auto configuration for pH or ORP operation
- Optional EasyCal calibration aid with automatic buffer recognition
- Junction boxes for convenient wiring
- Patented DryLoc® connector provides a quick and secure connection to the sensor
Standards:
- CE
- FCC
- China RoHS
- RoHS compliant
Product Details
- Manufacturer: GF Signet
- Part number: 3-2750-7
- Product type: Sensor Electronics
Review inputs, outputs, power and sensor compatibility.
| Compatible Electrodes | Signet DryLoc® pH and ORP Electrodes, Models 2724-2726, 2756-2757 Wet-Tap, 2764-2767, 2774-2777 |
|---|---|
| Operating Range pH | 0 to 14 pH |
| Operating Range ORP | ±2,000 mV |
| Response Time pH | < 6 sec. for 95% of change |
| Response Time ORP | application dependent |
| Materials In-line | Valox® (PBT) |
| Materials Submersible | CPVC |
| Cable | 4.6 m (15 ft) |
| Cable | 22 AWG |
| Power 12 to 24 VDC | ±10%, regulated for 4 to 20 mA output |
| Power 12 to 24 VDC | ±5% regulated recommended, 3 mA max., for digital (S3 L) output |
| Current Output pH | Fixed 4 to 20 mA, isolated, = 0 to 14 pH (custom scaling available with 0250 tool) |
| Current Output ORP | Fixed 4 to 20 mA, isolated, = -1000 to 2000 mV (custom scaling available from ± 000 mV with 0250 tool) |
| Max Loop Resistance | 100 ω max. @ 12 V / 325 ω max. @ 18 V / (600 ω max. @ 24 V) |
| Accuracy | ±32 μA |
| Resolution | ±5μ A |
| Update Rate | 0.5 seconds |
| Error Indication | 3.6 mA |
| Digital (S3 L) Output | Serial ASCII, TTL level 9600 bps |
| Accuracy pH | ± 0.03 pH @ 25 °C (± 0.03 pH @ 77 °F) |
| Accuracy ORP | ± 2 mV @ 25 °C (± 2 mV @ 77 °F) |
| Resolution pH | ≤ 0.01 pH |
| Resolution ORP | 1 mV |
| Temperature | ≤ 0.2 °C (0.36 °F) |
| Update Rate | 0.5 seconds |
| Available Data | Raw mV, pH or ORP, temperature (pH) |
| Error Indication | Open input diagnostic |
| Input Impedance, Z | >10 to the power 11 Ω |
| Operating Temperature submersible | 0 °C to 85 °C (32 °F to 185 °F) |
| Operating Temperature in-line | 0 °C to 110 °C (32 °F to 230 °F) |
| Storage Temperature | -20 °C to 85 °C (-4 °F to 185 °F) |
| Relative Humidity | 0 to 95%, non-condensing (without electrode connected) |