GF Signet 2260-V-1DNX-4 2260-X-XXXX-XX Ultrasonic Level Transmitter. Range: 0.2 to 4 m, Measuring

GF Signet 2260-V-1DNX-4 2260-X-XXXX-XX Ultrasonic Level Transmitter. Range: 0.2 to 4 m, Measuring

2260-X-XXXX-XX Ultrasonic Level Transmitter. Range: 0.2 to 4 m, Measuring for process monitoring and control
SKU:2260-V-1DNX-4
Model Number: 2260-X-XXXX-XX
$0.000

GF Signet 2260-V-1DNX-4 is the 2260-X-XXXX-XX Ultrasonic Level Transmitter. Range: 0.2 to 4 m, Measuring for process monitoring and control.


WHERE TO BUY?
Overview
Specification
Accessories
Overview

GF Signet 2260-V-1DNX-4 2260-X-XXXX-XX Ultrasonic Level Transmitter. Range: 0.2 to 4 m, Measuring

GF Signet 2260-V-1DNX-4 is the 2260-X-XXXX-XX Ultrasonic Level Transmitter. Range: 0.2 to 4 m, Measuring for process monitoring and control.

Specifications and Features

2260 Ultrasonic Level Transmitter

The type 2260 is a rugged, high performance ultrasonic secondary lightning protection level measurement transmitter, having transducer and processing electronics and a display/programming unit incorporated into a single housing.

All type 2260 Level Transmitters are using established high end pulse echo transducers, which provide narrow beam angles and reliable measurement ranges up to a distance of 15 meters.

For small, stand-alone tanks the transmitter provides a simple 2-wire 4 to 20 mA output, with additional power relay contacts. It can be programmed using push buttons and the large, graphic display. For large and/or multiple tank applications versions with HART interface are recommended, communicating directly with a panel mount controller or PLC. The HART protocol can easily be used for programming these versions.

  • Principle: non-contact ultrasonic transit time
  • Measuring range: 0.2…4 m, 0.25…6 m, 0.45…15 m
  • Sensor Type: PP or PVDF
  • Output: 4-20 mA, 2-wire; HART Protocol; Relay
  • Integrated display and programming buttons
  • Supply power: 12…36 V DC

Fields of Application:

  • River water
  • Seawater
  • Potable water
  • Demineralized water
  • Treated water

Advantages:

  • 2-wire compact transmitters
  • Non-contact level metering
  • Narrow 5° beam angle
  • Fully temperature compensated electronics
  • Outstanding signal processing software providing highly accurate measuring results
  • PP or PVDF sensor body provides best chemical resistance
  • Quick-set menu for efficient installation
  • Plug-in keypad and display
  • Switching relay for high / low alarm
  • 4 to 20 mA / HART interface
  • Secondary lightning protection

Standards:

  • CE
  • RoHS

Product Details

  • Manufacturer: GF Signet
  • Part number: 2260-V-1DNX-4
  • Product type: Transmitter

Review inputs, outputs, power and sensor compatibility.

Specification
Type2260-Y-YYY-4 , 2260-Y-YYY-6 , 2260-Y-YYY-15
Range0.2 to 4 m / 0.65 to 13 ft , 0.25 to 6 m / 0.82 to 20 ft , 0.45 to 15 m / 1.5 to 49 ft
Measuring Frequency80 kHz , 80 kHz , 40 kHz
Total Beam Angle6°, 5°, 5°
Accuracy *± (0.2 % of measured distance plus 0.05 % of range)
Resolution<2 m (6.6 ft): 1 mm (0.04 in.), 2 to 5 m (6.6 to 16.4 ft), 2 mm (0.08 in.), 5 to 10 m (16.4 to 32.8 ft): 5 mm (0.2 in.), >10 m (32.8 ft): 10 mm (0.39 in.)
Process Temperature-30 &deg;C to +90 &deg;C (-22 &deg;F to + 194 &deg;F)
Ambient Temperature-25 &deg;C to +70 &deg;C (-13 &deg;F to + 158 &deg;F)
Process Pressure (absolute)0.03 to 0.3 MPa (0.3 to 3 bar) 4.35 psi - 43.5 psi
Sensor BodyPP or PVDF
HousingPBT
Enclosure Material SensorIP68
Enclosure Material HousingIP67
Ingress Protection SensorIP68
Ingress Protection HousingIP67
Process Connection1 1/2&rdquo; BSP / NPT , 2&rdquo; BSP / NPT , DN125 / 5 inch fl ange
PP sensorEPDM
PVDF sensorFPM (Viton)
Outputs2-wire 4&ndash;20 mA , max. 600 Ohm; HART interface, Rt &gt;/= 250 Ohm &Omega;
Relay(SPDT) 250V AC, 3A AC1
Power Supply12 to 36 V DC / 44 to 800 mW
Power ConsumptionDC 3.6 W, AC 4 VA
Connection2 x M20x1,5 plastic cable gland: Cable: &Oslash;6 &hellip; 12 mm
General ApprovalsCE, RoHS
Accessories