Specifications and Features
2260 Ultrasonic Level Transmitter
The type 2260 is a rugged, high performance ultrasonic secondary lightning protection level measurement transmitter, having transducer and processing electronics and a display/programming unit incorporated into a single housing.
All type 2260 Level Transmitters are using established high end pulse echo transducers, which provide narrow beam angles and reliable measurement ranges up to a distance of 15 meters.
For small, stand-alone tanks the transmitter provides a simple 2-wire 4 to 20 mA output, with additional power relay contacts. It can be programmed using push buttons and the large, graphic display. For large and/or multiple tank applications versions with HART interface are recommended, communicating directly with a panel mount controller or PLC. The HART protocol can easily be used for programming these versions.
- Principle: non-contact ultrasonic transit time
- Measuring range: 0.2…4 m, 0.25…6 m, 0.45…15 m
- Sensor Type: PP or PVDF
- Output: 4-20 mA, 2-wire; HART Protocol; Relay
- Integrated display and programming buttons
- Supply power: 12…36 V DC
Fields of Application:
- River water
- Seawater
- Potable water
- Demineralized water
- Treated water
Advantages:
- 2-wire compact transmitters
- Non-contact level metering
- Narrow 5° beam angle
- Fully temperature compensated electronics
- Outstanding signal processing software providing highly accurate measuring results
- PP or PVDF sensor body provides best chemical resistance
- Quick-set menu for efficient installation
- Plug-in keypad and display
- Switching relay for high / low alarm
- 4 to 20 mA / HART interface
- Secondary lightning protection
Standards:
- CE
- RoHS
Product Details
- Manufacturer: GF Signet
- Part number: 2260-V-1DAX-15
- Product type: Transmitter
Review inputs, outputs, power and sensor compatibility.
| Type | 2260-Y-YYY-4 , 2260-Y-YYY-6 , 2260-Y-YYY-15 |
|---|---|
| Range | 0.2 to 4 m / 0.65 to 13 ft , 0.25 to 6 m / 0.82 to 20 ft , 0.45 to 15 m / 1.5 to 49 ft |
| Measuring Frequency | 80 kHz , 80 kHz , 40 kHz |
| Total Beam Angle | 6°, 5°, 5° |
| Accuracy * | ± (0.2 % of measured distance plus 0.05 % of range) |
| Resolution | <2 m (6.6 ft): 1 mm (0.04 in.), 2 to 5 m (6.6 to 16.4 ft), 2 mm (0.08 in.), 5 to 10 m (16.4 to 32.8 ft): 5 mm (0.2 in.), >10 m (32.8 ft): 10 mm (0.39 in.) |
| Process Temperature | -30 °C to +90 °C (-22 °F to + 194 °F) |
| Ambient Temperature | -25 °C to +70 °C (-13 °F to + 158 °F) |
| Process Pressure (absolute) | 0.03 to 0.3 MPa (0.3 to 3 bar) 4.35 psi - 43.5 psi |
| Sensor Body | PP or PVDF |
| Housing | PBT |
| Enclosure Material Sensor | IP68 |
| Enclosure Material Housing | IP67 |
| Ingress Protection Sensor | IP68 |
| Ingress Protection Housing | IP67 |
| Process Connection | 1 1/2” BSP / NPT , 2” BSP / NPT , DN125 / 5 inch fl ange |
| PP sensor | EPDM |
| PVDF sensor | FPM (Viton) |
| Outputs | 2-wire 4–20 mA , max. 600 Ohm; HART interface, Rt >/= 250 Ohm Ω |
| Relay | (SPDT) 250V AC, 3A AC1 |
| Power Supply | 12 to 36 V DC / 44 to 800 mW |
| Power Consumption | DC 3.6 W, AC 4 VA |
| Connection | 2 x M20x1,5 plastic cable gland: Cable: Ø6 … 12 mm |
| General Approvals | CE, RoHS |